• <br /> Page 2 of -. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS check treatment tank(s)for the presence of painting products,solvents or other chemicals or sediment <br /> that may impede the treatment process and/or damage the soil absorption cell(s). If high concentrations are detected have the contents of the tank(s) <br /> removed by a septage servicing operator prior to use. <br /> System start up shall not occur when soil conditions are frozen at the infiltrative surface. <br /> During extended power outages pump tanks may fill above normal highwater levels.When power is restored the excess wastewater will be discharged <br /> to the dispersal cell(s)in one large dose and may overload them resulting in the backup or surface discharge of effluent.To avoid this situation have the <br /> contests of the pump tank removed by a Septage Servicing Operator prior to restoring power to the effluent pump or contact oa Plumber or POWTS <br /> Maintainer to assist in manually operating the pump controls to restore normal levels within the pump tank. <br /> Do not drive or park vehicles over tanks and disposeral cells. Do not drive or park over, or otherwise disturb or compact,the area within 15 feet down <br /> slope of any mound or at-grade soil absorption area. <br /> Reduction or elimination of the following from the wastewater stream may improve the performance and prolong the life of the POWTS:antibiotics,baby <br /> wipes, cigarette butts, condoms, cotton swabs, degreasers, dental floss, diapers, disinfectants, fat,foundation drain (sump pump)discharge,fruit and <br /> vegetable peelings, gasoline, greases, herbicides, meat scraps, medications, oils, painting products, pesticides, sanitary napkins, tampons, and water <br /> softener brine. <br /> ABANDONMENT <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure that the system is properly and safely <br /> abandoned in compliance with s.Comm 83.33,Wisconsin Administrative Code: <br /> • All piping to tanks,pits and other soil absorption systems shall be disconnected and the abandoned pipe openings sealed. <br /> • The contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator(pumper). <br /> • After pumping,all tanks and pits shall be excavated and removed or their covers removed and the void space filled with soil,gravel or another inert <br /> solid material. <br /> CONTINGENCY PLAN <br /> If the POWTS fails and cannot be repaired the following measures have been,or must be taken,to provide a code compliant replacement system: <br /> ❑ A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption system. The replacement <br /> area should be protected from disturbance and compaction and should not be infringed upon by required setbacks from existing and proposed <br /> structure,lot lines and wells. Failure to protect the replacement area will result in the need for a new soil and site evaluation to establish a suitable <br /> replacement area.Replacement systems must comply with the rules in effect at the time of their permit issuance. <br /> ❑ A suitable replacement area is not available due to setback and/or soil limitations. If the soil absorption system cannot be rehabilitated and barring <br /> advances in POWTS technology,a holding tank may be installed as a last resort. <br /> XThe site has not been evaluated to identify a suitable replacement area.Upon failure of the POWTS a soil and site evaluation must be performed to <br /> locate a suitable replacement area.If no replacement area is available a holding tank may be installed as a last resort to replace the failed POWTS. <br /> ❑ Mound and at-grade soil absorption systems may be reconstructed in place following removal of the biomat at the infiltrative surface. <br /> Reconstructions of such systems must comply with the rules in effect at that time. <br /> WARNING: TREATMENT TANKS AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES AND LACK SUFFICIENT <br /> OXYGEN TO SUPPORT LIFE. NEVER. ENTER A TREATMENT TANK OR HOLDING TANK UNDER ANY <br /> a• CIRCUMSTANCE. DEATH MAY RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK IS VERY <br /> DIFFICULT. <br /> ADDITIONAL INFORMATION: <br /> POWTS INSTALLER POWTS MAINTAINER <br /> Name:.-5©H .1 YYl Name: .—b[.9-"f J'i€/-1• 1g- <br /> Phone: (v c) / tea 3 3 d Phone: Co 5-9a-3 60 3 <br /> • <br /> SEPTAGE SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> Name: S. aD£R k S <br /> /fie, y S�� Name: U,4+`d.� �ti.A) �''/ M 3,Le, /4,244_7# <br /> Phone: (D O S 8 cab Phone: CO-6 0/2,& 2_ - Sl c' <br /> This document is intended to meet minimum requirements of Ch. Comm 83.22(2)(b)(1)(d)&(f)and 83.54(1), (2)& (3),Wisconsin Administrative Code. <br /> Use of this document does not guarantee the performance of the POWTS. <br /> • <br /> 3/2/200 9-PO W TSplan.d o c <br />