Page'of Z" <br /> POWTS OWNER'S MANUAL & MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: R 0 ( ] Tank Manufacturer: 0 NA <br /> l� �/ (Septic ❑ Dose ❑ Holding Volume 1 OD(`) gal <br /> Permit: POWTS# Tank Manufacturer: ❑ NA <br /> P eptic r'6ose ❑ Holding Volume 5(o 0 gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: 9 ' ft <br /> Number of Bedrooms: . ❑ NA Horizontal Distance Tank(s)to Service Pad: 8 o ft <br /> Number of Public Facility Units: -N-NA Specific servicing mechanics must be provide if vertical is>15 feet or if <br /> Estimated (average) Flow: 3L717 gal/day horizontal is>150 feet.Specific instructions on plan addendum. <br /> Design (peak)Flow=estimated x 1.5: ,.715-0 gal/day <br /> In Situ Soil Application Rate: gal/day/ft2 Effluent Filter Manufacturer NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: <br /> Fats,Oil&Grease(FOG) 5530 mg/L Pump Manufacturer: 14 e-S , ❑ NA <br /> Biochemical Oxygen Demand(BOD5) _5220 mg/L ❑ NA Pump Model: S Z Z{•1 <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L ❑Mechanical Aeration ❑Peat Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L ❑ NA ❑Disinfection ❑Wetland <br /> A <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5) 530 mg/L J(in-Ground(gravity) ❑ In-Ground(pressure) ❑ NA <br /> Total Suspended Solids(TSS) 530 mg/L ❑ NA ❑At-Grade ❑Mound <br /> Fecal Colifomi(geometric mean) 55104 cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑ NA <br /> Other: ❑ NA Other: <br /> ❑ NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) hen combined sludge and scum equals one-third (1/3)of tank volume. <br /> ,When the high water alarm is activated. • <br /> Inspect condition of tank(s) At least once very 3 years. ❑ NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑ NA <br /> Clean effluent filter ❑ NA <br /> Inspect pump, pump controls&alarm ❑ NA <br /> Flush laterals and pressure test ❑ NA <br /> Other: ❑ NA <br /> Other: ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber, Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer, Septage Servicing Operator (pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.The dispersal cell(s)shall be visually inspected to check the effluent levels in the <br /> observation pipes and to check for any pending of effluent on the ground surface.The pending of effluent on the ground surface may indicate a failing <br /> condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of the <br /> tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment units, and any <br /> servicing at intervals of 512•months,shall be performed by a certified POWTS Maintainer. <br /> 3/2/2009-PO W TSpla n.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.