|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPFLO-2015-00010
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2015
>
DCPFLO-2015-00010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2015 10:44:42 AM
Creation date
10/23/2015 10:44:39 AM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPFLO-2015-00010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Approximately 0.5 miles upstream from the project site, Vinburn Road crosses the Maunesha <br /> River. The upstream structure is a single-span concrete flat slab bridge with concrete <br /> abutments. The structure is approximately 26.6 feet long between abutment faces. The clear <br /> roadway width is approximately 23.9 feet. The structure is not skewed. <br /> Approximately 0.5 miles downstream from the project site, USH 151 crosses the Maunesha <br /> River. The downstream structure is a single-span concrete T-beam bridge with concrete <br /> abutments. The structure is approxim ately 51.8 feet long between abutment faces. The clear <br /> roadway width is approximately 35.3 feet. The structure is skewed approximately 30 degrees. <br /> MAGNITUDE AND FREQUENCY OF FLOODS <br /> A flood frequency versus discharge analy sis of the Maunesha River drainage basin at the <br /> proposed site was performed. The design discharge for the 100-year frequency (regional) flood <br /> was determined by using Conger's Method (WRI-91-4128)for geographic region 5, as well as <br /> drainage basin corn parisons to similar watersheds. The drainage area at the site i s 24 square <br /> miles. The design regional flood discharge val ue adopted for the 100-year discharge is 1,200 <br /> cfs. <br /> The hydrology computations, dated February 13, 2014 were previously submitted on March 4, <br /> 2014 and were approved on June 27, 2014. T he relationship shown in Table 1 is based on the <br /> hydraulic analysis and is assumed for the project site. <br /> ANALYSIS OF HYDRAULIC CHARACTERISTICS <br /> The project site's hydraulic characteristics were modeled using the "Hydrologic Engineering <br /> Center-River Analysis System" (HEC-RAS) computer program. The hydraulic characteristics of <br /> the existing and various proposed conditions w ere modeled. <br /> Ayres Associates obtained cross section data and Manning's"n"values from the field survey <br /> and photographs. <br /> Six hydraulic cross sections were used to model this site. The cross sections are located <br /> approximately 70 feet, 30 feet, and 16 feet upstream and 16 feet, 30 feet, and 70 feet <br /> downstream from the existing Elder Lane centerline. <br /> Water surface shots were taken 940 feet upstream and 1,450 feet downstream of the existing <br /> bridge and at the existing bridge. The resulting 0.0004 ft/ft field survey hydraulic slope was not <br /> in close agreement with the 0.0015 ft/ft slope obtained from the quadrangle maps. A hydraulic <br /> slope of 0.0004 ft/ft was used as the starting stream slope for the analysis and the model <br /> agreed closely with flood history. <br /> The existing structure as well as various proposed structures were modeled. The results of the <br /> hydraulic analysis are shown in the attached Table 3. <br /> EXISTING STRUCTURE AND APPROACHES <br /> The existing structure is a single-span concrete T-Beam bridge with concrete abutments. The <br /> structure is approximately 34.9 feet long between abutment faces. The clear roadway width is <br /> approximately 26.8 feet. The structure is not skewed. The sufficiency rating was 40.1 on June <br /> 9, 2014. The existing structure is currently not posted. <br /> 2 u:\41-0668.00-dane county,town bristol,elder lane\reports\bsr\b-13-672_siz.doc <br /> 41-0668.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.