Laserfiche WebLink
ow.arke4 DIVISION OF INDUSTRY SERVICES <br /> }5�� , r9 10541 N RANCH RD <br /> 1.\4 p S HAYWARD WI 54843-6462 <br /> a� Contact Through Relay <br /> P httpj/dsps.wi.gov/programs/industry-services <br /> 1 www.Wisconsin.gov <br /> Ro4'ssloNpV Scott Walker,Governor <br /> Dave Ross,Secretary <br /> November 13,2015 <br /> CUST ID No, 697287 ATTN:POWTS Inspector <br /> STEVEN TESMER ENVIRONMENTAL HEALTH DIVISION <br /> ECKMAYER INC DANE COUNTY SPIA <br /> N8458 CTY HWY 0 1202 NORTHPORT DR RM 154 <br /> WATERLOO WI 53594-9403 MADISON WI 53704-2088 <br /> CONDITIONAL APPROVAL <br /> PLAN APPROVAL EXPIRES: 11/13/2017 Identification Numbers <br /> Transaction ID No.2626100 <br /> SITE: Site ID No. 814028 <br /> Red Door Restaurant Please refer to both identification numbers, <br /> 6925 Elder Ln above,in all correspondence with the agency. <br /> Town of Bristol, 53590 <br /> Dane County <br /> SE1/4,SE1/4,S22,T9N,R11E <br /> FOR: <br /> Description:Mound,75 restaurant seats,88 dining hall seats, 10 employees,2 floor drains <br /> Object Type:POWTS Component Manual,lRegtritea-Object ID No.: 1573078 <br /> Maintenance required; Replacement syste , 3,669 GPD Flow rate; 27 in Soil minimum depth to limiting factor from <br /> original grade; System(s):Mound Compote nt-ManUT f Ver.2,0,SBD-10691-P(N.01/01,R. 10/12),Pressure <br /> Distribution Component Manual-Ver.2.0,SBD-10706-P(N.01/01,R. 10/12); Aerobic Treatment Unit,Commercial <br /> System,Effluent Filter <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be constructed <br /> and located in accordance with the enclosed approved plans and with any component manual(s)referenced above. <br /> The owner,as defined in chapter 101.01(10),Wisconsin Statutes,is responsible for compliance with all code <br /> requirements. <br /> No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, <br /> stars. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> Key Item(s) <br /> • In the event this soil absorption system or any of its component parts malfunctions so as to create a health <br /> hazard,the property owner must follow the contingency plan as described in the approved plans.In addition,the <br /> owner must insure that the operation,maintenance and monitoring duties as described in section VIII of the <br /> mound component manual are complied with.A copy of this information must be given to the owner upon <br /> completion of the project. <br /> • The distribution cell is designed for wastewater strength with monthly averages of less than or equal to 20 <br /> mg/L of fats,oils and grease,less than or equal to 30 mg/L of biochemical oxygen demand and 30 mg/L total <br /> suspended solids and fecal coliform levels of less than 10,000 cfu/100 ml, <br /> " • Comm 83.21(2)(c)4.The application for a sanitary permit shall be accompanied with documentation that the <br /> master plumber or master plumber-restricted service who is to be responsible for the installation or modification <br /> of the POWTS,has completed approved training on the proposed POWTS technology or method. <br />