Laserfiche WebLink
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page to of 7 <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner f4I1/2) LDEJZ E L. Tank Manufacturer W reSelL ❑NA <br /> Permit# <br /> [-Septic ❑ Dose ❑.Holding Volume: iv) (gal) <br /> DESIGN PARAMETERS Tank Manufacturer. ❑:NA <br /> Number of Bedrooms: 14 ❑ NA ❑Septic C3-1Dose ❑ Holding Volume: $C 6 (gal) <br /> Number of Public Facility Units: ❑ NA Vertical Distance Tank Bottoms)to Service Pad:(p (ft) <br /> Estimated(average)Flow: 140 O (gal/day) Horizontal Distance Tank(s)to Service Pad: IQ' (ft) <br /> Design(peak)Flow=(estimated x 1.5): Specific servicing mechanics must be provided if vertical is>15 feet or <br /> �n66 (g aUda y) if horizontal is>150 feet. Specific instructions to be provided on back. <br /> In Situ Soil Application Rate: 5 (gal/dayift2) Effluent Filter Manufacturer. 10?La k <br /> 0 N <br /> Standard(Domestic)Influent/Effluent Monthly average Effluent Filter Model: /�pL S Z 5 <br /> Fags,Oil&Grease (FOG) s30 mg/L Dose Manufacturer R 15S y Fla Ar <br /> Biochemical Oxygen Demand (BOD5) 4'10 mg/L ❑ NA / ❑NA <br /> --Total Suspended Solids(MS) 5150 mg/L Model 3 4 LA / 6 e DRAW O a o rn/ <br /> High Strength Influent/Effluent Monthly average Pretreatment Unit l <br /> (FOG) >30 mg/L Manufacturer. <br /> >220 m ❑NA <br /> �(TSS) >150 mg/L �A ❑Mechanical Aeration ❑Peat Filter <br /> Pretreated Effluent Monthly average ❑Disinfection ❑Wetland <br /> ❑Sand/Gravel Fitter ❑Other <br /> (8005) 530 mg/L Soil Absorption System <br /> (TSS) 530 mg/L D-I*A <br /> Fecal Conform(geometric mean) 5104 ❑In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> M ❑DrlGrane aximum Effluent Particle Size X in dia. ❑ NA ❑D ❑Mound ip-Line ❑Other her. <br /> Other ❑ NA Other ❑NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) Eli-VUf en combined sludge and scum equals one-third())of tank volume <br /> 0 When the high water alarm is activated <br /> Inspect condition of tank(s) At least once every: ❑month(s) <br /> 3 C3year( (Maximum(Maum 3 years) ❑NA <br /> . <br /> Inspect dispersal cell(s) At least once every: 3 0 s( )s) (Maximum 3 years) ❑ NA <br /> Clean effluent fitter At least once every: E-lhonth(s) ❑N <br /> t3 ❑year(s) — <br /> Inspect Rissy Float&Controls At least once every: ❑month(s) ❑ NA <br /> Flush laterals and pressure test At least once every: ❑month(s) li?-NA <br /> ❑year(s) <br /> Other At least once every: ❑month(s) <br /> ❑year(s) <br /> Other. <br /> ❑NA <br /> MAINTENANCE INSTRUCTIONS <br /> .t Inspections of tanks and soil absorption systems shall be made by an individual carrying one of the following licenses or certifications: <br /> 'Master Plumber, Master Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer or Septage Servicing Operator (pumper). <br /> Tank inspections must include a visual inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and a check for any back up or ponding of effluent on the ground surface. The soil <br /> absorption system shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent <br /> on the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(4)or more of the tank volume,the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator(pumper)and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services,including but not limited to the servicing of effluent filters,mechanical or pressurized components, pretreatment units, <br /> and any servicing at intervals of 512 months,shall be-performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br /> GMW-005(02/05) <br />