Laserfiche WebLink
START UP AND OPERATION Page of <br /> 7 <br /> For new construction, prior to use of the POWTS check treatment tank(s) for the presence of painting products, solvents or other <br /> chemicals or sediment that may impede the treatment process and/or damage the soil absorption system. If high nitrations are <br /> detected have the contents of the tank(s)removed by a Septage Servicing Operator(pumper)prior to use. _ <br /> Pump tanks may fill above normal highwater levels prior to startup or due to pump failures. Start up or restoration of power under these <br /> conditions is not recommended,as the excess wastewater will be discharged to the soil absorption system in one large dose causing an <br /> overload that may result in the backup or surface discharge of effluent and damage to the system. To avoid this situation have the <br /> contents of the ptmip tank removed by a Septage Servicing Operator(pumper)prior to restoring power to the pump or contact a Plumber <br /> or POWTS Maintainer to assist in manually operating the pump controls until normal effluent levels are restored within the pump tank. <br /> System start up shall not occur when soil conditions are frozen at the infiltrative surface. <br /> Do not drive or park vehicles over tanks or the soil absorption system. Do not drive or park over, or otherwise disturb or compact,the <br /> area within 15 feet down slope of any mound or at-grade soil absorption area. <br /> Reduction or elimination of the following from the wastewater stream may improve the performance and prolong the fife of the treatment <br /> tanks and soli absorption system: acids, antibiotics, baby wipes, cigarette butts, condoms, cotton swabs, degreasers, dental floss, J: <br /> diapers, disinfectants,fats,foundation drain(sump pump)discharge,fruit and vegetable peelings, gasoline, greases, herbicides, meet <br /> scraps,medications,oils,painting products,pesticides,sanitary napkins,solvents,tampons,and water softener brine discharge. <br /> ABANDONMENT <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure that the system is properly <br /> and safely abandoned in compliance with s.Comm 83.33,Wisconsin Administrative Code: <br /> • All piping to tanks,pits and other soil absorption systems shall be disconnected and the abandoned pipe openings sealed. <br /> • The contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator(pumper). <br /> • After pumping, all tanks and pits shall be excavated and removed or their covers removed and the void space filled with soil, <br /> gravel or another inert solid material. <br /> CONTINGENCY PLAN <br /> If the POWTS fails and cannot be repaired the following measures have been, or must be taken, to provide a code compliant <br /> replacement system: <br /> l3�A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption system. <br /> The replacement area should be protected from disturbance and compaction and should not be infringed upon by required <br /> setbacks from existing and proposed structure,lot lines and wells. Failure to protect the replacement area will result in the need <br /> for a new soil and site evaluation to establish a suitable replacement area. Replacement systems must comply with the rules in <br /> effect at the time of their permit issuance. <br /> ❑ A suitable replacement area is not available due to setback and/or sod limitations. if the soil absorption system cannot be <br /> rehabilitated and barring advances in POWTS technology,a holding tank may be installed as a last resort. <br /> ❑ The site has not been evaluated to identify a suitable replacement area. Upon failure of the POWTS a sod and site evaluation <br /> must be performed to locate a suitable replacement area. If no replacement area is available a holding tank may be installed as a <br /> last resort to replace the failed POWTS. <br /> ❑ Mound and at-grade soil absorption systems may be reconstructed in place following removal of the biomat at the infiltrative <br /> surface. Reconstructions of such systems must comply with the rules in effect at that time. <br /> WARNING TREATMENT TANKS, PUMP TANKS, AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES OR LACK <br /> SUFFICIENT OXYGEN TO SUSTAIN LIFE. NEVER ENTER ANY TANK UNDER ANY CIRCUMSTANCE. DEATH MAY <br /> RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK MAY NOT BE POSSIBLE. <br /> ADDITIONAL INSTRUCTIONS: <br /> POWTS INSTALLER POWTS MAINTAINER <br /> Name AAThcnl'( eo pch Mr-1(L Name /wig., 6-,ee. / 11m <br /> Phone aOd-6¢3 -Z�&l Phone <br /> 196g_4113 -0881 <br /> SEPTAGE SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> Name Name DA.J£ et tlr4T-‘e E& '.i4GA ITN <br /> Phone Phone t pg_ 242-(S 15 <br /> This document was drafted by the staffs of the Green Lake, Marquette and Waushara County POWTS regulatory agencies in compliance with sections <br /> Comm 83.22(2)(b)(1)(d)8(t)and 83.54(1),(2)&(3),Wisconsin Administrative Code. <br />