Laserfiche WebLink
Page 1 of 2 <br /> POWTS OWNER'S MANUAL& MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> • <br /> Owner: ERIK&CATHERINE RANHEIM Tank Manufacturer: CREST <br /> I XI Septic I I Dose I I Holding Volume 1600 gal <br /> Permit: POWTS# Tank Manufacturer: N/A <br /> I I Septic I I Dose I Holding Volume gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: <15'ft <br /> Number of Bedrooms: 4 Horizontal Distance Tank(s)to Service Pad: <150' ft. <br /> Number of.Public Facility Units: N/A Specific servicing mechanics must be provided if vertical is>15 ft. <br /> Estimated (average) Flow: 400 gal/day or if horizontal is>150 ft.Specific instructions on plan addendum. <br /> Design (peak) Flow=estimated x 1.5: 600 gal/day <br /> In Situ Soil Application Rate: 0.6 gal/day/ft2 Effluent Filter Manufacturer and Model: <br /> Standard Domestic Influent/Effluent Monthly average BEST GF10 OR EQUIVALENT <br /> Fats,Oil&Grease(FOG) 5 30 mg/L Pump Manufacturer and Model: N/A <br /> Biochemical Oxygen Demand(BOD5) <_220 mg/L <br /> Total Suspended Solids(TSS) 5 150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats,Oil&Grease(FOG) >30 mg/L I I Mechanical Aeration I I Peat Filter <br /> Biochemical Oxygen Demand(BOOS) >220 mg/L _ N/A n Disinfection I Wetland N/A <br /> Total Suspended Solids(TSS) >150 mg/L I I Sand/Gravel Filter n Other: <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BOD5)5 30 mg/L I I In-ground(gravity) I I In-ground(pressure) <br /> Total Suspended Solids(TSS)5 30 mg/L N/A © At-grade n Mound <br /> Fecal Coliform(geometric mean) 5104 cfu/100m1 I I Drip-line n Other: <br /> Maximum Effluent Particle Size: 1/8 in.dia. <br /> Other: N/A Other: N/A <br /> MAINTENANCE SCHEDULE <br /> Service Event Service <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third(1/3) of tank volume. <br /> When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once every 3 years <br /> Inspect dispersal cell(s) At least once every 3 years <br /> Clean effluent filter Every year or as needed within a 3 year interval <br /> Inspect pump, pump controls &alarm N/A <br /> Flush laterals and pressure test N/A <br /> Other: N/A <br /> Other: N/A <br /> MAINTENANCE INSTRUCTIONS <br /> Inspection of tanks and dispersal cell(s)shall be made by an individial carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer,POWTS Inspector,POWTS Maintainer,Septage Servicing Operator(pumper).Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum <br /> and a check for any backup or ponding of effluent on the ground surface.The dispersal cell(s)shall be visually inspected to check the effluent levels in <br /> the observation pipes and to check for any ponding of effluent in the ground surface.The ponding of effluent on the ground surface may indicate a <br /> failing condition and require the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume,the entire contents of <br /> the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> All other services,including but not limited to the servicing of effluent filters,mechanical or pressurized components,pretreatment units,and any <br /> servicing at intervals of 5 12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br />