Laserfiche WebLink
KYLE D DUMBLETON Page 3 9/5/2008 <br /> • IBC 1609.5.1 Roof deck shall be designed to withstand wind pressures of ASCE 7. <br /> • IBC 2902.1/Comm 62.2902(1)(a)2.-Drinking facilities are required based on the type of occupancy and in <br /> the minimum number shown in Table 2902.1,unless water is served in restaurants or where other acceptable <br /> arrangements are made to provide drinking water. <br /> Reminders <br /> • IBC 803.5-Interior wall&ceiling finishes shall have a flame spread index not greater than Table 803.5. <br /> • IBC 906.1 -Provide fire extinguishers per IFC 906. <br /> • Fire extinguishers shall be selected, installed and maintained in accordance with IFC 906 and NFPA 10. <br /> • IBC 1011.1 -Exits and exit access doors shall be marked by an approved exit sign readily visible from any <br /> direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit <br /> or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that <br /> no point in an exit access corridor is more than 100 feet from the nearest visible exit sign. Address the need <br /> for 90 minute continued illumination in case of power loss. <br /> • IBC 1210.2-Walls within 2 feet of urinals and water closets shall have a smooth,hard,nonabsorbent surface, <br /> to a height of 4 feet above the floor,and except for structural elements,the materials used in such walls shall <br /> be of a type that is not adversely affected by moisture. <br /> • IBC 1405.3.2-Provide flashing and weepholes in the first course of masonry above grade and above supports. <br /> • IBC 1507.2.8.2-Provide ice dam protection for the roof assembly as required per this section. Designer to <br /> indicate requirement and assembly on plans. <br /> • IBC 1609.1 -Buildings,structures and parts thereof shall be designed to withstand the minimum wind loads <br /> prescribed herein.Decreases in wind loads shall not be made for the effect of shielding by other structures. <br /> • IBC 1907.7-Minimum concrete covering of reinforcing is required. <br /> • IBC 2104.1.8-Weep holes provided in the outside wythe of masonry walls shall be at a maximum spacing of <br /> 33 inches on center. Weep holes shall not be less than 3/16 inch in diameter. <br /> • IBC 2304.9.1-Connections for wood members shall be at least the number and size of nails or fasteners in <br /> wood members as set forth in Table 2304.9.1,unless more are required by design method. <br /> • IBC 2603.4.1.3 No thermal barrier or sprinkler shall be required where foam plastic insulation in walk-in <br /> coolers or freezers does not exceed 4 inches,has a covering of at least 0.032 inch aluminum or 0.016 inch <br /> corrosion-resistant steel,a maximum 75 flame spread index and the coolers and freezers are under 400 sf in <br /> aggregate floor area. The foam plastic may be up to 10 inches thick with a thermal barrier. <br /> • IBC 2603.9 Provide test data per FM 4880,UL 1040 or UL 1715 in the end-use configuration performed on <br /> finished material,including joints. Acceptance of the large scale test data shall permit the use of foam plastic <br /> insulation to skip the requirements associated with sections 2603.4 through 2603.6. <br /> • ICC/ANSI A117.1 Sec.601.1 -Plumbing elements and facilities in this building shall be accessible,unless <br /> meeting an exception to the scoping provisions of this code,and shall be designed to provide required <br /> minimum wheelchair turning space, fixture positioning,clearances and heights,grab bars,accessible <br /> accessories and controls. <br /> • Comm 62.1101(2)/ANSI A117.1 602,305,306&309-Provide required accessible drinking fountains and <br /> water coolers with the required clear floor space,heights and controls. <br /> • Comm 62.1101.2/ANSI A117.1 604.5-Provide a grab bar behind the water closet which is a minimum of 24" <br /> (36"when possible)and offset 12"to the open side of the water closet. The grab bar beside the water closet <br /> shall be at least 42"and shall extend a minimum 54" from the wall behind the water closet.The height of the <br /> grab bar shall be between 33"-36"above the finished floor per 609.4. A vertical grab bar 18"minimum in <br />