KYLE D DUMBLETON Page 4 9/5/2008 <br /> length shall be mounted with the bottom of the bar located between 39"and 41"above the floor and the center <br /> line of the bar located between 39"&41" from the rear wall. <br /> • ICC/ANSI A117.1 Sec.604.5.1 -The side wall grab bar shall be a minimum 42 inches in length and 12 <br /> inches maximum from the back wall extending a minimum total of 54 inches from the back wall. <br /> • Comm 62.1101.2/ANSI A117.1 604.5.1 -In addition to the horizontal side wall grab bar,provide a vertical <br /> grab bar 18"minimum in length mounted with the bottom of the bar located between 39"and 41" above the <br /> floor and the center line of the bar located between 39"&41"from the rear wall. <br /> • ICC/ANSI A117.1 Sec.604.5.2 The rear wall grab bar shall be 24 inches minimum in length,centered on <br /> the water closet,unless meeting an exception to this section. Where space permits a 36 inch minimum grab <br /> bar shall be provided and be offset to the transfer side of the water closet. <br /> • ICC/ANSI A117.1 Sec.904.3-Sales and service counters required to be accessible shall be located adjacent <br /> to a walking surface and shall have a counter 36 inches maximum above the floor,with a 36 inch minimum <br /> length for a parallel approach,or 30 inch minimum length for a forward approach. <br /> • ICC/ANSI A117.1 Sec.604.5 Grab bars shall be located on a side wall that is 16 to 18 inches from the <br /> centerline of the water closet and on the wall behind the water closet,unless meeting an exception to this <br /> section. These grab bars shall comply with Section 604.5.1 and 604.5.2. <br /> • Comm 62.1101(2)/ANSI A117.1 602,305,306&309-Provide required accessible drinking fountains and <br /> water coolers with the required clear floor space,heights and controls. <br /> • ICC/ANSI A117.1 Sec.606.6-Pipe protection shall be provided under lavatories and sinks for the drain and <br /> water pipes or otherwise be configured to protect against contact. There shall be no sharp or abrasive surfaces <br /> under lavatories or sinks. <br /> Our agency offers a number of worksheets and checklists for the Commercial Building Code at <br /> http://commerce.wi.gov/SB/SB-CommBldgPlanRevinfo.html that may assist you in preparing your submittal. <br /> Send your resubmittal into the address listed above,unless otherwise noted,and the department will review the <br /> resubmittal within 5 working days of receipt date. Please include a copy of this letter with your resubmittal. <br /> Designer shall identify plan revisions by a readily discernible means such as bubbling,shading, highlighting, <br /> hatching or clouding the changed areas prior to plan resubmittal. Failure to do so may delay review. <br /> If the above requested information and/or plans are not received within 30 business days of the date of this <br /> correspondence,this submittal will be returned denied. No fees will be refunded,and a new fee,application form, <br /> and submittal of plans/specifications will be required should you desire to continue with this project. The code in <br /> effect at the time of new submittal would apply. <br /> If you have any questions,after reading the above comments and related code sections cited,please call me at the <br /> telephone number below. <br /> Sincerely, <br /> David Wallace,P.E. <br /> Building Plan Reviewer,Integrated Services <br /> (608)261-6540,7:45-4:30 <br /> david.wallace@wisconsin.gov <br /> cc: Steve Gothard, State Building Inspector,(608)235-0568,Monday <br /> Building Inspection Town of Windsor <br /> Harmeet Singh,Windsor Travel Plaza <br />