Pages of S <br /> 411 other services, including but not limited to the servicing of effluent filters,mechanical or pressurized components, pretreatment units, and any <br /> servicing at intervals of 512 months,shall be performed by a certified POWTS Maintainer. <br /> 4 service report shall be provided to the Environmental Health and Labs Division of Public Health Madison and Dane County within 30 days of <br /> completion of any service event <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS,check treatment lank(s)for the presence of painting products,solvents or other chemicals or sediment <br /> that may impede the treatment process and/or damage the soil absorption cell(s).If high amounts of these materials are detected in the tanks,have the <br /> contents of the tank(s)removed by a septage servicing operator prior to use. <br /> System start up shall not occur when soil conditions are frozen at the infiltrative surface. <br /> During extended power outages pump tanks may fill above normal high water levels.When power is restored the excess wastewater will be discharged <br /> to the dispersal cell(s)in one large dose and may overload them resulting in the backup or surface discharge of effluent To avoid this situation have the <br /> contests of the pump tank removed by a Septage Servicing Operator prior to restoring power to the effluent pump or contact a Plumber or POWTS <br /> Maintainer to assist In manually operating the pump controls to restore normal levels within the pump tank. <br /> Do not drive or park vehicles over tanks and dispersal cells.Do not drive or park over,or otherwise disturb or compact,the area within 15 feet down <br /> slope of any mound or at-grade soil absorption area. <br /> Reduction or elimination of the following from the wastewater stream may improve the performance and prolong the life of the POWTS:antibiotics,baby <br /> wipes,cigarette butts,condoms,cotton swabs,degreasers,dental floss,diapers,disinfectants,fat,foundation drain(sump pump)discharge,fruit and <br /> vegetable peelings,gasoline,greases,herbicides,meat scraps,medications,oils,painting products,pesticides,sanitary napkins,tampons,and water <br /> softener brine. <br /> ABANDONMENT <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure that the system Is properly and safely <br /> abandoned in compliance with s. SPS383.33,Wisconsin Administrative Code: <br /> • All piping to tanks,pits and other soil absorption systems shall be disconnected and the abandoned pipe openings sealed. <br /> • The contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator(pumper). <br /> • After pumping,all tanks and pits shall be excavated and removed or their covers removed and the void space filled with soil,gravel or another inert <br /> solid material <br /> CONTINGENCY PLAN <br /> If the POWTS fails and cannot be repaired the following measures have been,or must be taken,to provide a code compliant replacement system: <br /> tif A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption system.The replacement <br /> area should be protected from disturbance and compaction and should not be infringed upon by required setbacks from existing and proposed <br /> structure,lot lines and wells.Failure to protect the replacement area will result In the need for a new soill and site evaluation to establish a suitable <br /> replacement area.Replacement systems must comply with the rules in effect at the time of their permit Issuance. <br /> ❑ A suitable replacement area is not available due to setback and/or soil limitations.If the soil absorption system cannot be rehabilitated and barring <br /> advances In POWTS technology,a holding tank may be Installed as a last resort. <br /> ❑ The site has not been evaluated to identify a suitable replacement area.Upon failure of the POWTS a soil and site evaluation must be performed to <br /> locate a suitable replacement area.If no replacement area is available a holding tank may be installed as a last resort to replace the failed POWTS. <br /> ❑ Mound and at-grade soli absorption systems may be reconstructed In place following removal of the biomat at the infiltrative surface. <br /> Reconstructions of such systems must comply with the rules In effect at that time. <br /> WARNING: TREATMENT TANKS AND HOLDING TANKS MAY CONTAIN POISONOUS GASSES AND LACK SUFFICIENT <br /> OXYGEN TO SUPPORT LIFE. NEVER ENTER A TREATMENT TANK OR HOLDING TANK UNDER ANY <br /> CIRCUMSTANCE. DEATH MAY RESULT. ESCAPE OR RESCUE FROM THE INTERIOR OF A TANK IS VERY <br /> `�a l'' DIFFICULT. <br /> ADDITIONAL INFORMATION: <br /> POWTS INSTALLER POWTS MAINTAINER <br /> Name: Name: <br /> Phone: Phone: <br /> SEPTAGE SERVICING OPERATOR(PUMPER) LOCAL REGULATORY AUTHORITY <br /> Name: Name: Public Health-Madison&Dane County <br /> Phone: Phone: 608-242-6515 <br /> This document is Intended to meet minimum requirements of Ch. SPS383.22(2)(bx1)(d)&(f)and383.54(1),(2)&(3),Wisconsin Administrative Code. <br /> Use of this document does not guarantee the performance of the POWTS. <br /> 3/&2010-PO W TSMGTplan,doc <br />