|
Help
|
About
|
Sign Out
Home
Browse
Search
DCPZP-2016-00717
DaneCounty-Planning
>
Zoning
>
1 Permits
>
2010s
>
2016
>
DCPZP-2016-00717
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2017 3:13:20 PM
Creation date
3/2/2017 4:04:11 PM
Metadata
Fields
Template:
Zoning Permits
AccelaLink
DCPZP-2016-00717
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Public Health Pag�5 ot� <br /> HconbppevplenndpinCe` POWTS OWNER'S MANUAL& MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner: / Tank Manufacturer: /fit C-/4'✓C ❑NA <br /> //,57.24 ES iT JE.-/, ^// -151 Septic ❑Dose ❑Holding Volume /4'7' gal <br /> Permit: POWTS// Tank Manufacturer: /14-C 7C ❑NA <br /> ❑Septic la Dose ❑Holding Volume I, gal <br /> DESIGN PARAMETERS Vertical Distance Tank Bottom(s)to Service Pad: /Y ft <br /> Number of Bedrooms: 3 ❑NA Horizontal Distance Tank(s)to Service Pact: // d ft <br /> Number of Public Facility Units: a}NA Specific servicing mechanics must be provide if vertical is>15 feel or if <br /> Estimated(average)Flow: 3 OD gal/day horizontal is>150 feet Specific instructions on plan addendum. <br /> Design(peak)Flow=estimated x 1.5: .V.5--ca gal/day <br /> In Situ Soil Application Rate: p. S gal/day/rt' Effluent Filter Manufacturer ❑NA <br /> Standard Domestic Influent/Effluent Monthly average Effluent Filter Model: A` / (• <br /> Fats.Oil&Grease(FOG) 530 mg/L Pump Manufacturer: ❑NA <br /> Biochemical Oxygen Demand(BODO) 5220 mg/L ❑NA Pump Model: p /j/ <br /> Total Suspended Solids(TSS) 5150 mg/L Pretreatment Unit <br /> High Strength Influent/Effluent Monthly average Manufacturer: <br /> Fats.Oil&Grease(FOG) >30 mg/1. ❑Mechanical Aeration ❑Peal Filter <br /> Biochemical Oxygen Demand(BOD5) >220 mg/L ye NA ❑Disinfection ❑Wetland 1NA <br /> Total Suspended Solids(TSS) >150 mg/L ❑Sand/Gravel Filter ❑Other: <br /> ~ <br /> Pretreated Effluent Monthly average Soil Absorption System <br /> Biochemical Oxygen Demand(BODO) 530 mg/L *In-Ground(gravity) ❑In-Ground(pressure) ❑NA <br /> Total Suspended Solids(TSS) 530 mg/L 12-NA ❑At-Grade ❑Mound <br /> Fecal Colilorm(geometric mean) 510'cfu/100m1 ❑Drip-Line ❑Other: <br /> Maximum Effluent Particle Size: 1/8 in dia. ❑NA <br /> Other: t NA Other: CaNA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Pump out contents of tank(s) '1 When combined sludge and scum equals one-third(1/3)of tank volume. <br /> 50 When the high water alarm is activated. <br /> Inspect condition of tank(s) At least once very 3 years. ❑NA <br /> Inspect dispersal cells(s) At least once very 3 years. ❑NA <br /> Clean effluent filter ❑NA <br /> Inspect pump,pump controls 8 alarm ❑NA <br /> Flush laterals and pressure test El.NA <br /> Other: t2 NA <br /> Other: &NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications:Master Plumber,Master <br /> Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer. Septage Servicing Operator(pumper). Tank inspections must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined sludge and scum and <br /> a check for any back up or ponding of effluent on the ground surface.If the volume of sludge and scum is less than one—third(1/3)of the liquid volume <br /> of the tank,the tank does not need to be pumped and identifying cracks in floor or walls of the tank may not be possible at that time.The dispersal cellist <br /> shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface.The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(1/3)or more of the tank volume.the entire contents of the <br /> lank shall be removed by a Seplaae Servicing Operator and disposed of in accordance with chapter NR 113,Wisconsin Administrative Code. <br /> e?v n y.rowr$L IG men d« <br />
The URL can be used to link to this page
Your browser does not support the video tag.