Laserfiche WebLink
Subsurface Exploration and Foundation Evaluation <br /> Proposed Golden Oil Refueling Station <br /> Stoughton, Wisconsin <br /> PSI Project No. 0092822 <br /> Page 3 <br /> Field Exploration <br /> Nine (9) soil test borings were drilled for this project to a depth of about 10 to 17.5 feet below <br /> the existing ground surface. The number, depths, and locations of the borings were provided <br /> by the client. The borings were located in the field by the drill crew utilizing conventional taping <br /> procedures referenced to existing site features and apparent property lines. They are <br /> estimated to be accurate to within a few feet. <br /> The surface elevations shown on the logs were estimated by interpolation of a 1-foot contour <br /> map of the property, provided by Excel Engineering. The elevations are estimated to be <br /> accurate to within about 1-foot. <br /> The soil test borings were performed with a truck-mounted rotary drilling rig utilizing continuous <br /> flight hollow stem augers to advance the holes. Representative samples were obtained by the <br /> Standard Penetration Test (SPT) method using split-spoon sampling procedures in general <br /> accordance with ASTM D-1586 procedures. Samples were collected at 2'/ foot intervals to 10 <br /> feet, and then at 5-foot intervals thereafter to the end of the borings. As an exception, samples <br /> were obtained at 2-foot intervals at the borings performed within the proposed pavement <br /> and/or stormwater management areas. The standard penetration value (N) is defined as the <br /> number of blows of a 140-pound hammer, falling thirty (30) inches, required to advance the <br /> split-spoon sampler one (1) foot into the soil. The sampler is lowered to the bottom of the drill <br /> hole and the number of blows recorded for each of the three (3) successive increments of six <br /> (6) inches penetration. The "N" value is obtained by adding the second and third incremental <br /> numbers. The SPT provides a means of estimating the relative density of granular soils and <br /> comparative consistency of cohesive soils, thereby providing a method of evaluating the <br /> relative strength and compressibility characteristics of the subsoils. <br /> The SPT soil samples were transferred into clean glass jars immediately after retrieval, and <br /> returned to the laboratory upon completion of the field operations. Samples will be discarded <br /> unless other instructions are received. All soil samples were visually classified by a soil <br /> engineer in general accordance with the Unified Soil Classification System (ASTM D-2488-75). <br /> The samples collected within the stormwater management areas were classified by a certified <br /> soil tester in general accordance with USDA National Resources Conservation Service textural <br /> soil classification procedures. A description of the subsurface conditions encountered at each <br /> boring location is shown on the enclosed Soil Boring Logs. After completion of the borings, the <br /> auger holes were backfilled to the ground surface with bentonite chips. <br /> A copy of the Soil Boring Logs and Boring Location Diagram (Figure 1) are enclosed in the <br /> Appendix. The soil stratification shown on the logs represents the approximate soil conditions <br /> in the actual boring locations at the time of the exploration. The terms and symbols used on <br /> the logs are described in the General Notes found in the Appendix. <br /> Laboratory Physical Testing <br /> Soil samples obtained from the exploration were visually classified in the laboratory, and <br /> subjected to testing, which included moisture content determination. Selected cohesive soil <br /> samples were tested in unconfined compression with a controlled strain loading rate and/or <br />